Reichert IOPac Standard Instrukcja Użytkownika Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 11
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
All claims made by manufacturer
COMPANY MODEL ALIGNMENT SYSTEM
Topcon Medical iTrace Combo Visual auto-align, auto-capture
Systems Function Analyzer auto-fogging
Welch Allyn 14010 direct view/data acquisition
SureSight Autorefractor
MEASURING
COMPANY MODEL PRINCIPLE METHOD
Marco 3D Wave dynamic spatial optical path
skiascopy difference
Ophthonix Inc. Z-View holographic binocular viewing
grating viewing, monocular
measurement
Topcon iTrace Combo Infrared laser Auto-capture with
Medical Systems Visual Function ray tracing monocular/binocular
Analyzer open-field and Badal
Optometer fixation
COMPANY MODEL STIMULUS AREA OF FIELD
Carl Zeiss Humphrey Field Goldmann std. 90°
Meditec Analyzer II-
i
proj. size III only;
Model 720i Heijl-Krakau fixation
monitor & video eye
monitor
Carl Zeiss Humphrey Field Goldmann std. proj. 90°
Meditec Analyzer II-
i
size I, II, III, IV, V;
Model 740i Heijl-Krakau fixation
monitor & video eye
monitor; gaze tracking
Carl Zeiss Humphrey Field Goldmann std. proj. 90°
Meditec Analyzer II-
i
size I, II, III, IV, V; Heijl-Krakau
Model 745i fixation monitor & video eye
monitor; gaze tracking
Carl Zeiss Humphrey Field Goldmann std. proj. 90°
Meditec Analyzer II-
i
size I, II, III, IV, V; Heijl-Krakau
Model 750i fixation monitor & video eye
monitor; head tracking;
vertex monitor; gaze tracking
Carl Zeiss Humphrey FDT frequency doubled 30°
Meditec Visual Field sinusoidal gratings
Instrument (0.25 cpd; 25 Hz)
with frequency
doubling
Carl Zeiss Humphrey frequency doubled 30°
Meditec Matrix Visual sinusoidal gratings
Field Instrument
with frequency
doubling
Carl Zeiss SITA SWAP blue light; Goldmann n/a
Meditec std. proj. size V stimulus
AUTOREFRACTORS
WAVEFRONT ABERROMETERS
VISUAL ACUITY GLARE TESTING KERATOMETER ADDITIONAL FEATURES
no no yes Integrated ray-tracing aberrometry, corneal topography, auto-refractometry, auto-keratometry, pupillometry in one device;
multi-zonal refraction analysis at user-defined zone sizes for assessing photopic and scotopic vision.
no no no Features Wavefront Sensing Technology; less than 5 seconds per eye test time; data acquisition from 14”; child-friendly; battery
operated and portable; weighs 2 lbs.; IR data transfer to cordless printer.
INTERNAL OPD/
NUMBER OF POINT SPREAD LENTICULAR ZERNIKE
DATA POINTS FUNCTION DIFFERENCE OUTPUT ADDITIONAL FEATURES
1,440 yes yes WF Refraction & RMS value Topographer; Wavefront analyzer; OPD; internal OPD; pupillometer; Angle Kappa;
on thermal tape. Zernike map spherical aberration of cornea; mesopic & photopic pupil displayed; combined with
displays bar graphs, WF automated phoropter performs the Marco H-D Eye Exam; XP; Celeron M1.5 GHz
error & RMS values given. Processor; EMR-ready through Marco Connect.
>10,000 over displayed & no 2nd to 6th order The Z-View is designed specifically for dispensing practitioners to prescribe iZon
6 mm pupil printed as wavefront-guided lenses; wholly contained; ultramodern design; non-Hartmann-
convolved image Shack; contemporary design; compact size.
256 rapid sequential true, yes yes; including multizonal 5-in-1 functionality also includes corneal topography, auto-refraction w/multi-zone
points through directly-measured Zernike displayed as bar analysis for photopic and scotopic conditions, pupillometry and keratometry;
2 mm-8 mm pupils PSF graphs, coefficients, or binocular open-field fixation; accommodation volume; VFA Summary display;
combined RMS and computer independent.
individual RMS term
PERIMETERS
STANDARD TESTS PRINTER TEST STRATEGIES ADDITIONAL FEATURES
threshold: 3 central, 1 periph. built-in thermal; can be threshold: SITA, FastPac; Now with VFI,
EasyConnect
and HFA-NET Pro standard. Computerized silent
pattern; 4 screening central, hooked up to HP full screen: age ref. strategy; projection system; reduces threshold testing by up to 70%; 12 test patterns
3 full-field periph. patterns LaserJet threshold-related; 2-zone, w/static threshold & screening strategies to 90º; STATPAC2 software compares
3-zone & quantify defects results w/age-matched normative data; CRT touch screen; wheelchair-
accessible table w/built-in printer avail. DICOM Gateway compatible (optional).
HFA II-
i
comes with the capability to connect to FORUM Data Management system.
FORUM allows real-time viewing of reports or images from supported networked
ZEISS and non-ZEISS instruments. FORUM supports bi-directional workflow for
supported DICOM enabled devices, reducing charting errors and increasing patient
throughput. Additionally, HFA, when utilized with FORUM, enables the archiving of
raw data, automatic back up after every exam and the creation of combination
structure function reports (with Cirrus HD-OCT).
threshold: 4 central, built-in thermal; threshold: SITA, FastPac; Now with VFI,
EasyConnect
, Guided Progression Analysis (GPA) and HFA-NET Pro
2 periph. patterns; can be hooked full screen: age ref. strategy; standard. 19 test patterns; user-designed custom testing w/range to 90º;
screening: 5 central up to HP LaserJet threshold-related; 2-zone, patented gaze-tracking system provides true reliability assessment without
screening, 7 full-field/ 3-zone & quantify defects disrupting testing. Built-in 40 GB data storage; compares multiple STATPAC results
periph. patterns via print-out; Goldmann I-V foveal threshold testing; red/blue testing; custom
testing avail.; built-in VGA monitor hookup for remote viewing. DICOM Gateway.
compatible (optional). HFA II-
i
comes with the capability to connect to FORUM
Data Management system. FORUM allows real-time viewing of reports or images
from supported networked ZEISS and non- ZEISS instruments. FORUM supports
bi-directional workflow for supported DICOM enabled devices, reducing charting
errors and increasing patient throughput. Additionally, HFA, when utilized with
FORUM, enables the archiving of raw data, automatic back up after every exam
and the creation of combination structure function reports (with Cirrus HD-OCT).
threshold: 4 central, built-in thermal; threshold: SITA, FastPac; Includes all features of 740i; STATPAC for blue/yellow perimetry. DICOM Gateway
2 periph. patterns: can be hooked full screen: age ref strategy; compatible (optional). HFA II-
i
comes with the capability to connect to FORUM Data
screening: 5 central, up to HP LaserJet threshold-related; 2-zone, Management system. FORUM allows real-time viewing of reports or images
7 full-field/periph patterns 3-zone & quantity defects from supported networked ZEISS and non- ZEISS instruments. FORUM supports
bi-directional workflow for supported DICOM enabled devices, reducing charting
errors and increasing patient throughput. Additionally, HFA, when utilized with
FORUM, enables the archiving of raw data, automatic back up after every exam
and the creation of combination structure function reports (with Cirrus HD-OCT).
threshold: 4 central, built-in thermal; threshold: SITA, FastPac; Model 750i includes all of the previous features plus head tracking; automatic
2 periph. patterns; can be hooked full screen: age ref. strategy; vertex monitoring; automatic pupil measurement; std. blue/yellow testing; kinetic
screening: 5 central, up to HP LaserJet threshold-related; 2-zone, testing and keyboard; all models upgradable. DICOM Gateway compatible
7 full-field/periph. 3-zone & quantify defects (optional). HFA II-
i
comes with the capability to connect to FORUM Data
patterns; SSA Kinetic Management system. FORUM allows real-time viewing of reports or images from
supported networked ZEISS and non- ZEISS instruments. FORUM supports
bi-directional workflow for supported DICOM enabled devices, reducing charting
errors and increasing patient throughput. Additionally, HFA, when utilized with
FORUM, enables the archiving of raw data, automatic back up after every exam
and the creation of combination structure function reports (with Cirrus HD-OCT).
screening: C-20 n/a n/a 45-second screening; 4-minute threshold; 19 lbs.; easy to use; age-related
full threshold: C-20, normative database.
N-30
screening: N-30,24-2 external 8.5 x 11 screening: MOBS Fast screen <45 seconds; 20GB HD; CD RW drive; floppy drive; external keyboard;
threshold: N-30-F, color printer threshold: Zest, MOBS small footprint; statistical analysis w/age-related normative database; serial field,
24-2 FDT, 30-2 FDT video eye monitoring; no eye patch needed; no trial lens needed out to ± 3.00D;
Macula: 10-2, Macula ambient light testing.
Threshold (4°)
threshold; single field n/a 24-2 Available as a licensed option on all HFA II & II-i models; 745-750; blue-yellow
analysis report threshold testing in 3 to 6 minutes per eye. Makes blue-yellow testing a
clinically practical tool for early detection of glaucoma. Improved reproducibility;
larger dynamic range & higher sensitivity than other SWAP tests.
Przeglądanie stron 1
1 2 3 4 5 6 7 ... 10 11

Komentarze do niniejszej Instrukcji

Brak uwag